Layer | Electrode Type | Electrode ID | Why |
4 | Pad | 74 | Carleton flagged this pad as dead. We saw no cosmic on it and were unable to see a MIP signal on the scope while running at 2600V with CO2 only. |
Layer | Leak Rate (mbar/min) | Pass/Fail? |
1 | 0.013 | Pass |
2 | 0.017 | Pass |
3 | 0.017 | Pass |
4 | 0.017 | Pass |
Date | Layer | Time (absolute or duration) | VMon[V] | IMon[µA] | Cicumstance | ||
2020-01-14 | 3 | 1s | 3097.5 | 3100 | 1 | 0 | HV operation at set voltage |
2020-01-14 | 2 | 1s | 3100.5 | 3100.5 | 3.5 | 0 | HV operation at set voltage |
2020-01-14 | 2 | 1s | 3100.5 | 3100 | 2.5 | 0 | HV operation at set voltage |
2020-01-14 | 2 | 1s | 3100.5 | 3100.5 | 3 | 0 | HV operation at set voltage |
2020-01-14 | 2 | 1s | 3097.5 | 3100 | 2.5 | 0 | HV operation at set voltage |
2020-01-14 | 2 | 1s | 3097 | 3100 | 1.5 | 0 | HV operation at set voltage |
I | Attachment | History | Action | Size | Date | Who | Comment |
---|---|---|---|---|---|---|---|
![]() |
ql2p6_HV_01142020.png | r1 | manage | 117.2 K | 2020-02-04 - 22:47 | ZhelunLi | |
![]() |
ql2p6_HV_01152020.png | r1 | manage | 117.2 K | 2020-02-04 - 22:47 | ZhelunLi |