Goal: correct Vdep obtained from simulation; then compare to data Why: two reasons: 1) correct for annealing (done in reality, not in simulation) 2) correct for temperature and frequence (scale to f=10kHz and t = 20 º C) 1) annealing correction gc = 1.49e-2 1/cm phi = 1e15 neq/cm^2 ga = 1.81e-2 1/cm tau_a (60ºC) = 24.1 min t = 80 min ga * phi * TMath::Exp(-t/tau_a) (double)6.54692161401129150e+11 gc * phi (double)1.49000000000000000e+13 gc * phi - ga * phi * TMath::Exp(-t/tau_a) (double)1.42453078385988711e+13 A_annealing~ 4 % effect 2) A_CV correction factor data) t= -20 ºC, f = 1 kHz simu) t= 300 K, f = 1kHz scaling to f=10 kHz, t = 20 ºC: data) A_CV^data = 0.93 simu) A_CV^simu = 0.85 A_CV ~ 9 % effect so, Vdep^data = 340 V Vdep^simu = 621 V corrected, Vdep^data = 316 V Vdep^simu = 486 V diff [%] = 54 Errors? a) e_phi = 8% b) e_CV_corr = ? c) e_fit = ? (Expect HUGE) d) e_annealing_correction = ?